COMPARISON OF GEOSTRESS MEASUREMENT BETWEEN AE METHOD WITH STRESS RELIEF BY OVERCORING IN SILIN POWER STATION,GUIZHOU PROVINCE
-
摘要: 为了研究思林电站地下厂房区地应力状态,作者采用声发射法(AE)和现场套心应力解除法对拟建的思林电站进行地应力测量。声发射法测得最大主应力值为15.9MPa,套心法测得的最大主应力方向为NE 70.9°,最大主应力值为16.03MPa,表明在同一测点用两种不同的测量方法所测的结果一致。Abstract: In order to study the stress condition of the underground area at Silin power station,Guizhou Province,which will be constructed,the geostress measurements by acoustic emission(AE) and stress relief methods are carried out here.The results show that the magnitude of maximum principal stress by AE is 15.9MPa,and the direction of the maximum principal stress is NE 70.9° and its magnitude 16.03 MPa by overcoring,suggesting that at the same position the results obtained by two methods are very similar and believable.
-
Key words:
- acoustic emission /
- AE /
- measurement of geostress /
- stress-relief method
点击查看大图
计量
- 文章访问数: 186
- HTML全文浏览量: 46
- PDF下载量: 6
- 被引次数: 0